张明铎,蒋渭鑫.检定声级计有关性能用猝发声的研究[J].,2003,22(4):45-48 |
检定声级计有关性能用猝发声的研究 |
Study on the tone burst used to check the performances of sound levelmeters |
|
中文摘要: |
在相关标准中,规定检定声级计有关性能用的猝发声必须‘零起零落”。本文通过实验验证指出,猝发声“零起零落”与否,对声级计的检定结果有明显影响,但其差别远小于相应客差的1/10,这一差别对计量检定要求来说是很小的,可忽略不计。因而,在声级计检定中没有必要强调猝发声必须“零起零落”。 |
英文摘要: |
It is demanded in the correlative standards that the tone burst, used for inspecting sound level meters, must be "0-on and 0-off". This paper makes some experimental study on the influence of this requirement. The results show that whether the tone burst is "0-on and 0-off" or not, it will affect the results of check up. However, the difference between the two results is much smaller than 1/10 of the correlative tolerances such that it can be ignored for the inspection purpose. Thus, it seems not necessary to stress that the tone burst must be "0-on and 0-off" in inspecting sound level meters. |
DOI:10.11684/j.issn.1000-310X.2003.04.012 |
中文关键词: 声级计 猝发声 计量检定 |
英文关键词: Sound level meter Tone burst Verification |
基金项目: |
|
摘要点击次数: 2390 |
全文下载次数: 788 |
查看全文
查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|