文章摘要
侯东,段 炼,曹春诚,邴 龙,马超群,陈 鹤.35 kV油浸式配电变压器噪声与振动测试*[J].,2020,39(6):964-968
35 kV油浸式配电变压器噪声与振动测试*
Noise and vibration test of 35 kV oil-immersed distribution transformer
投稿时间:2020-05-09  修订日期:2020-11-01
中文摘要:
      配电变压器振动与噪声问题日益凸出,研究配电变压器振动与噪声特性对其振动与噪声控制具有重要意义。本文以一台35kV/800kVA油浸式配电变压器为研究对象,对不同激励电压作用下配电变压器铁心振动、油箱振动以及噪声进行测试。测试结果表明:配电变压器铁心、油箱振动与噪声具有相似频谱特征,均表现出以100Hz、200Hz为主要峰值的频谱特征;随着激励电压增加,变压器振动及噪声水平明显增大;变压器油箱振动值大于铁心,侧面振动水平较高,油箱正面和顶面振动水平略低。测试结果准确的反应了配电变压器铁心与油箱的振动与噪声特性,对于其噪声振动控制具有参考价值。
英文摘要:
      The vibration and noise problems of distribution transformers are increasingly prominent. Studying the vibration and noise characteristics of distribution transformers are significance for noise control. A 35kV/800kVA oil-immersed distribution transformer is used as the research object. The core vibration, tank vibration and noise of distribution transformer are tested under different excitation voltages. The test results show that core vibration、tank vibration and noise of distribution transformer have similar spectrum characteristics,all of them exhibit spectrum characteristics with 100Hz and 200Hz as the main peaks;As the excitation voltage increases, the transformer vibration and noise levels increase significantly;The vibration value of the transformer oil tank is higher than that of the iron core, the vibration level of the front and top surfaces of the oil tank is slightly lower. The test results accurately reflect the vibration and noise characteristics of the distribution transformer core and oil tank, which have a reference value for its noise and vibration control.
DOI:10.11684/j.issn.1000-310X.2020.06.021
中文关键词: 配电变压器, 振动与噪声特性, 铁心振动
英文关键词: Distribution transformer, Vibration and noise characteristics, Core vibration
基金项目:
作者单位E-mail
侯东* 全球能源互联网研究院有限公司 hd61140161@163.com 
段 炼 国网呼伦贝尔供电公司  
曹春诚 国网呼伦贝尔供电公司  
邴 龙 国网呼伦贝尔供电公司  
马超群 国网呼伦贝尔供电公司  
陈 鹤 国网呼伦贝尔供电公司  
摘要点击次数: 1257
全文下载次数: 1080
查看全文   查看/发表评论  下载PDF阅读器
关闭