文章摘要
张丽敏,祖峰磊,邱小军.反馈有源噪声控制系统水床效应的分析与改善[J].,2010,29(6):401-408
反馈有源噪声控制系统水床效应的分析与改善
Analysis and improvement on waterbed effect of feedback active noise control system
  
中文摘要:
      本文依据反馈有源噪声控制原理分析了水床效应存在机理,以一模拟反馈有源噪声控制系统作为实例介绍了水床效应的分析方法,提出了通过展宽噪声放大频段和均匀噪声放大频段内的噪声放大量来优化反馈控制器,改善水床效应的方法。采用数字反馈控制器实现了水床效应的改善,给出了具体设计过程,并且考虑了数字时延对系统性能影响。仿真和实验表明了所提出方法的有效性。
英文摘要:
      This paper analyzes the mechanism of waterbed effect based on the principles of the feedback active noise control by using an analog feedback active noise control system.An approach to reduce the waterbed effect is proposed by broadening the frequency band of noise amplification and flatting the noise amplification in the whole band.Finally,a digital filter design process to reduce the waterbed effect is presented,which takes into account the effects of the digital delay on system performance.Simulation and experiment results show the effectiveness of the proposed method.
DOI:10.11684/j.issn.1000-310X.2010.06.001
中文关键词: 水床效应  噪声控制  反馈有源控制  数字滤波器
英文关键词: Waterbed effect  Noise control  Feedback active control  Digital filter
基金项目:国家自然科学基金资助项(10804049)
作者单位
张丽敏 南京大学声学研究所近代声学教育部重点实验室 
祖峰磊 南京大学声学研究所近代声学教育部重点实验室 
邱小军 南京大学声学研究所近代声学教育部重点实验室 
摘要点击次数: 2617
全文下载次数: 1096
查看全文   查看/发表评论  下载PDF阅读器