中文摘要:
      针对空调室外机背面位置处在压缩机5280rpm转速下的出现两倍频(176Hz)噪声峰值异常高的问题,基于双转子压缩机工作原理,计算双转子压缩机吸排气过程的两倍频转动力矩;建立空调室外机整机有限元模型,施加两倍频转动力矩,应用模态线性叠加法计算整机的频率响应,初步确定在172Hz附近背板位置处存在共振,导致测点位置处两倍频异常高。基于间接边界元法,将整机频响计算结果导入声学仿真软件中,进一步计算钣金框体6个部位对测点位置处的声学贡献量,最终确定背板、中隔板、前面板共振导致测点位置两倍频过高。基于形貌优化技术,重点优化背板的压型,将固有频率从172Hz提高至201.5Hz,避免背板共振;同时前面板增加压型凸包,中隔板局部贴附阻尼,将整机176Hz的两倍频峰值从55.74dBA降低至45.11dBA,有效地提升空调室外机的声品质。
英文摘要:
      Aiming at the problem of abnormally twice fundamental frequency (176Hz) noise peak at the back of the AC outdoor unit when the compressor speed is of 5280rpm, based on the working principle of the dual-rotor compressor, calculate the twice fundamental frequency torque of the double-rotor compressor in the suction and discharge process. Establish a finite element model of the outdoor unit, apply twice fundamental frequency torque, and calculate the frequency response of the unit using the modal superposition method. It is preliminarily determined that there is resonance at the back plate near 172 Hz, resulting in an abnormally twice fundamental frequency at the measuring position. Based on the indirect boundary element method, the frequency response calculation result of the finite element model is imported into the acoustic simulation software, and the acoustic contribution of the 6 parts of the sheet metal frame to the measuring point is further calculated, and it is finally determined that the resonance of the back plate, partition plate, and front panel causes excessively high frequency peak at the measuring point. Based on the topography optimization technology, optimize the profile of the back plate to increase the natural frequency from 172Hz to 201.5Hz, which in turn avoids resonance of back plate; at the same time, the front panel is provided with a profiled convex hull, and the partition plate is partially attached with damping, making the peak of twice fundamental frequency(176Hz) reduced from 55.74dBA to 45.11dBA, effectively improving the sound quality of the AC outdoor unit.
DOI:10.11684/j.issn.1000-310X.2022.02.008
中文关键词: 空调室外机,双转子压缩机,两倍频,激励提取,模态叠加,间接边界元,形貌优化
英文关键词: AC  outdoor unit, double-rotor  compressor, twice  fundamental frequency, modal  superposition, indirect  boundary element, topography  optimization
基金项目:
作者单位E-mail
杜明龙* 青岛海信日立空调系统有限公司 青岛 duminglong@hisensehitachi.com 
丛辉 青岛海信日立空调系统有限公司 青岛 conghui@hisensehitachi.com 
邓玉平 青岛海信日立空调系统有限公司 青岛 dengyuping@hisensehitachi.com 
闫丽俊 青岛海信日立空调系统有限公司 青岛 yanlijun@hisensehitachi.com 
摘要点击次数: 724
全文下载次数: 1001
查看全文   查看/发表评论  下载PDF阅读器
关闭