中文摘要:
      针对变电站噪声测量容易受外界干扰的问题,提出了一种抗干扰变电站噪声测量系统实现方法,利用最小值控制递归平均算法实时估计每个时频点变电站噪声存在概率,再综合成每个1/3倍频程中外界干扰信号存在概率;对干扰信号存在的1/3倍频程,不进行1/3倍频程噪声更新,从而避免外界干扰信号对变电站噪声测量的影响。仿真结果证明,该方法可以有效减小瞬态干扰对变电站噪声的影响。
英文摘要:
      An implementation method of anti-interference substation noise measurement system is proposed to avoid being affected by external interference. The minimum control recursive average algorithm is used to estimate the existence probability of substation noise at each frequency bin in real time., and then integrate it into 1/3 octave band. For the 1/3 octave band where the interference signal exists, no noise update is performed, so as to avoid the influence of interference signal on the noise measurement. The simulation results prove that this method can effectively reduce the impact of transient interference on substation noise.
DOI:10.11684/j.issn.1000-310X.2022.06.010
中文关键词: 变电站  噪声  1/3倍频程测量  抗干扰  最小值控制递归平均算法
英文关键词: Substation  Noise  1/3 octave band measurement  Anti-interference  Minimum control recursive average algorithm
基金项目:
作者单位E-mail
卢铃* 国网湖南省电力有限公司电力科学研究院 luling11@mails.ucas.ac.cn 
蔡炜 国网湖南省电力有限公司娄底供电分公司 娄底 744872372@qq.com 
曹浩 国网湖南省电力有限公司电力科学研究院 长沙 国网电力设施噪声与振动实验室 长沙 309087135@qq.com 
武帅兵 中科传启(苏州)科技有限公司 shuaibing.wu@gmail.com 
吴鸣 中国科学院噪声与振动重点实验室(声学研究所) mingwu@mail.ioa.ac.cn 
彭继文 国网湖南省电力有限公司电力科学研究院 长沙 国网电力设施噪声与振动实验室 长沙 18973102398@163.com 