文章摘要
张嵩阳,何强,肖伟民,王磊磊,王东晖.干式空心电抗器的试验模态特征分析[J].,2020,39(5):730-735
干式空心电抗器的试验模态特征分析
Experimental modal analysis of dry-type air-core reactor on eigensystem realization algorithm method
投稿时间:2020-04-17  修订日期:2020-08-31
中文摘要:
      干式空心电抗器在变电站运行中发挥着重要作用。为了有效控制电抗器噪声的环境影响,该文利用特征系统实现方法,针对通电作用下的电抗器模态特性进行了试验分析。结果表明,干式空心电抗器的前5阶固有频率出现在其通电运行状态的作用频率中,并可能成为其在通电运行条件下发生噪声增强和设备损坏的重要原因,该研究将为改进其设备共振问题提供重要依据。
英文摘要:
      It is an important part of the power system operation for the dry-type air-core reactor. This paper investigates the experimental modal characteristics in the work condition based on the eigensystem realization algorithm method. The result shows that the lower order resonance frequency of the dry-type air-core reactor existed in the work excitation frequency, which was one of the most important reasons of the equipment damage and noise enhancement during the work condition. The result provides the imperative data for improving the resonance of the equipment.
DOI:10.11684/j.issn.1000-310X.2020.05.011
中文关键词: 电力高压设备  干式空心电抗器  试验模态分析  降噪
英文关键词: high voltage equipment  dry-type air-core reactor  experimental modal analysis  noise control
基金项目:国网河南省电力公司项目
作者单位E-mail
张嵩阳 国网河南省电力公司电力科学研究院 370219259@qq.com 
何强* 全球能源互联网研究院有限公司 heqiang0927@163.com 
肖伟民 北京市劳动保护科学研究所 13522261603@126.com 
王磊磊 国网河南省电力公司电力科学研究院 wll9109@163.com 
王东晖 国网河南省电力公司电力科学研究院 7548813@qq.com 
摘要点击次数: 1267
全文下载次数: 970
查看全文   查看/发表评论  下载PDF阅读器