Page 24 - 《应用声学)》2023年第5期
P. 24
916 2023 年 9 月
织结构信息,对B线的识别更加可靠有效,可以为临 lung ultrasound[J]. Intensive Care Medicine, 2012, 38(4):
床经验有限的医生提供准确的辅助诊断信息,减缓 577–591.
[6] Moshavegh R, Hansen K L, Sørensen H M, et al. Novel
肺超声诊断的学习曲线,提高诊断准确率。
automatic detection of pleura and B-lines (comet-tail arti-
facts) on in vivo lung ultrasound scans[C]// Spie Medical
参 考 文 献 Imaging, 2016.
[7] Corradi F, Brusasco C, Vezzani A, et al. Computer-
[1] Volpicelli G, Elbarbary M, Blaivas M, et al. Interna-
aided quantitative ultrasonography for detection of pul-
tional evidence-based recommendations for point-of-care
monary edema in mechanically ventilated cardiac surgery
lung ultrasound[J]. Intensive Care Medicine, 2012, 38(4):
patients[J]. Chest, 2016, 150(3): 640–651.
577–591.
[8] Cristiana B, Grzegorz T, Seungsoo K, et al. Automated
[2] Lichtenstein D, Mezière G. A lung ultrasound sign al-
lung ultrasound B-line assessment using a deep learn-
lowing bedside distinction between pulmonary edema
ing algorithm[J]. IEEE Transactions on Ultrasonics Ferro-
and COPD: the comet-tail artifact[J]. Intensive Care
electrics and Frequency Control, 2020, 67(11): 2312–2320.
Medicine, 1998, 24(12): 1331–1334.
[3] Jambrik Z, Monti S, Coppola V, et al. Usefulness of ultra- [9] Shannon C E. A mathematical theory of communica-
sound lung comets as a nonradiologic sign of extravascu- tion[J]. Bell Systems Technical Journal, 1948, 27(4):
lar lung water[J]. American Journal of Cardiology, 2004, 623–656.
93(10): 1265–1270. [10] Soldati G, Demi M, Smargiassi A, et al. The role of ul-
[4] Jambrik Z, Gargani L, Adamicza A, et al. B-lines quan- trasound lung artifacts in the diagnosis of respiratory dis-
tify the lung water content: a lung ultrasound versus lung eases[J]. Expert Review of Respiratory Medicine, 2019,
gravimetry study in acute lung injury[J]. Ultrasound in 13(2): 163–172.
Medicine & Biology, 2010, 36(12): 2004–2010. [11] Bandt C, Pompe B. Permutation entropy: a natural com-
[5] Volpicelli G, Elbarbary M, Blaivas M, et al. Interna- plexity measure for time series[J]. Physical Review Let-
tional evidence-based recommendations for point-of-care ters, 2002, 88(17): 174102.